Roof Inspection Report Example

Roof-only inspection example. 18-year-old architectural shingle, granule loss, flashing failures at chimney, ridge ventilation review.

Roof inspection example showing asphalt shingle granule loss
Roof inspection example showing asphalt shingle granule loss

01 · Sample findings

Annotated findings from this report.

Note Covering Material

Architectural asphalt shingle, GAF Timberline, manufactured 2008. 18 years old at time of inspection.

Concern Granule Loss

Moderate-to-heavy granule loss on south and west slopes. End-of-life wear pattern.

Major Chimney Flashing

Step flashing at chimney is rusted through in two locations. Active water entry likely during wind-driven rain.

Note Ridge Ventilation

Ridge vent installed continuously. Soffit intake present and unobstructed.

Full report download includes 25+ additional findings with photo evidence and a defect schedule.