Radon Inspection Report Example
48-hour continuous monitor radon measurement example. Basement placement, 7.2 pCi/L average, mitigation recommended per EPA action level.
01 · Sample findings
Annotated findings from this report.
Continuous monitor placed in finished basement, 24 inches above floor, away from exterior walls per EPA protocol.
Average pCi/L: 7.2 — exceeds EPA action level of 4.0 pCi/L. Mitigation recommended.
Maximum hourly reading 14.1 pCi/L at hour 18. Indicates active soil-gas entry.
Sub-slab depressurization system recommended. Typical Minnesota installation $1,200–$2,200.